I am a cable operator looking for someone who could set up an all inclusive solution for provisioning, etc. to launch my Arris 1000 CMTS in a new system. If you would send me your info at office@mptelco.com. Looking to move quickly. Thanks.
I have a strange problem on some of the Terayon Bluewave CMTSs. These boxes have been in service for a couple of years now, without major problems. I use DOCSIS2.0 modems and configurations only, I don't have any older modems. The thing that happens is, some of the CPEs cannot access the DNS servers. Here are the simptoms:
- modems register without problems
- CPEs receive their IPs and other stuff from DHCP no problem
- CPEs CAN ping anything on internet (based on IP only)
- CPEs CANNOT resolve any FQDN
FEB 01 09:25:30: %C3-5-R102.0: Retries exhausted for polled CM - MAC Addr: 001a.6660.8174
FEB 01 09:25:30: %C3-5-R104.0: Failed to receive Periodic RNG-REQ from modem (SID 46),timing-out SID.
FEB 01 09:29:33: %C3-5-R101.0: No Ranging Requests received from POLLED CM (CMTS generated polls). (16 logged)
FEB 01 09:29:33: %C3-5-R102.0: Retries exhausted for polled CM - MAC Addr: 001a.6660.8174
FEB 01 09:29:33: %C3-5-R104.0: Failed to receive Periodic RNG-REQ from modem (SID 46),timing-out SID.
Getting cable modems to work is a piece of cake for me. Getting Analog Telephone Adapters to work with Asterisk over cable modems is easy for me too. For some reason, I am having troubles with the EMTAs specifically the Arris TM502G. The funny thing is that I have access to Arris and ALL of the documentation. I have the cable modem part working fine. The thing I can't figure out is how to tell the Linux dhcpd.conf to send DHCP option 122 to the cable modem part of the TM502G to trigger the dhcp/tftp process of its MTA. Can anyone give me some clues on this?
We just installed a Arris C3 CMTS and are sending the IF output to a EMCEE Transmiter for our MMDS wireless cable plant. The CMTS does not seem to be outputing enough IF to allow the transmitter to come on line fully. Any ideas?
I did not know where to post something like this, but we are in need of a used docsis 1.0 cmts with 2-3 upstreams and 1 downstream. We would like if it could be Arris 1000 cmts, but any other unit can also be offered.
Hello,
I am trying to find any information regarding this CMTS device, but it seems that company does not exist anymore.
Can anyone share any light on these devices ? Are they any good ?
I am investigating developing or adapting an open source application for provisioning CMs and MTAs.
Does anyone who is using, has used or tried out DOCSIS_SERVER from accesscom.ca, care to share their experiences.
I am specially intrested in CM and MTA loads they have on it if they have it in production. Bad experiences if they have had any. Manual (human) effort in data entry.