Hi all,
I would like to short the ranging time of CMs connected to Arris C3 CMTS. From my experience to the other CMTS-es I configured ranging-backof to 1 4, and it works, but in Arris C3 CMTS even with this parameter configured, some of the modems are staying for long in init(r1) mode.
Does anybody know what else I need to reconfigure?
Thanks
Astrit,
Astrit kjo ndoshta do te ndihmoje pak, sigurisht qe duhet qe per çdo upstream te konfigurosh te njejtin parameter:
cable upstream x data-backoff automatic
cable upstream x range-backoff automatic
Pershendetje
I've found a solution to this problem.
With the following parameters configured the CMs are ranging very quickly:
interface Cable 1/0
cable insertion-interval 5
cable upstream x.x range-backoff 1 4
Zubz3R0, the data-backoff parameters take place after CM has been ranged.
Astrit,