I have a problem with our BSR1000 which have been working great for 3-4 years now.
After a power failure last week I have some cable modems coming online, but no data are sent through.
The status for the modem on the BSR1000 reads "online(un)".
Manual says:
online(un):
CM registered, but not enabled data. Fail to
verify modem’s identity by BPI module.
Has anybody seen this problem on the BSR? And hopefully has a solution?
Nothing has changed since before the power failure, and the config files are the same.
Thanks,
Jan O Greger
Check the ToD server and the time on the BSR to ensure it's correct -- that's the only time I've seen large scale BPI issues.
Hi Jan,
I recommend you setup an sntp server. check the time on your cmts, do a show clock.
Regards
Carl