Hello guys!!
We have 1 UBR10K working in 8x4 bonding, but now there is a second ubr on which we are trying to configure the thing differently
For example, on the first ubr, the configuration looks like this:
so we have 4 downstreams from /0-/3, and 4 downstreams from 0/4:
.....
cable fiber-node 26
downstream Integrated-Cable 5/0/0 rf-channel 0-3
downstream Integrated-Cable 5/0/4 rf-channel 0-3
upstream Cable 5/0 connector 0-3
cable fiber-node 27
downstream Integrated-Cable 5/0/1 rf-channel 0-3
downstream Integrated-Cable 5/0/4 rf-channel 0-3
upstream Cable 5/0 connector 4-7
cable fiber-node 7
downstream Integrated-Cable 5/0/3 rf-channel 0-3
downstream Integrated-Cable 5/0/4 rf-channel 0-3
upstream Cable 5/0 connector 12-15
.........
And on the second we need to do something like this:
and not use 0/4
.....
cable fiber-node 1
downstream Integrated-Cable 5/0/0 rf-channel 0-3
downstream Integrated-Cable 5/0/1 rf-channel 0-3
upstream Cable 5/0 connector 0-3
cable fiber-node 2
downstream Integrated-Cable 5/0/2 rf-channel 0-3
downstream Integrated-Cable 5/0/3 rf-channel 0-3
upstream Cable 5/0 connector 8-11
.....
I try to do everything by analogy, but I come across some difficulties
Who can tell is it possible at all and how can we to do it right way please?
Yes you can do it either way
But your proposed way isn't super efficient
Maybe have a look at the info here
https://docsis.org/comment/5866#comment-5866