Attachment | Size |
---|---|
run_10k_filtered.txt | 72.44 KB |
I've a doubt about the possibility to configure a UBR10k (PRE2 + 4x MC5x20) and RFGW-1 EQAM. I would like to configure two nodes with 8DS each (16DS in total) exclusively from the RFGW, so we will use the US from the MC5x20 LC and 16 DS from RFGW, no DS will be used on LC. Is this possible ? How could I adapt actual config. (attached) to achieve such configuration ?
Thnks,C.
Do you have a DTI server ?
Yes, Timecreator 1000.
Yes, this can be done.
1) You will first need to upgrade your RFGW1 to Ajax code 06.01.x
2) You will need to buy the Octal and Data license for the RFGW1 to run 8 RF channels on a single port
3) I run depi tunnels between the RFGW1 and 10k not the old school method
4) Remember when you move from 4 channels on the RFGW1 to 8 channels you lose half the service groups. That is to say a fully populated 5x20 10k has 36 four channel service groups .. It will now have 18.
Hi mjkatona,
Could you bring me a deeper insight regard to the fourth point you made??? I didn't understand. I will appreciate it!
Regards