Cisco ubr10k bonding on MC5x20 + SPA24XDS SFP without TC1000 | docsis.org

You are here

Cisco ubr10k bonding on MC5x20 + SPA24XDS SFP without TC1000

2 posts / 0 new
Last post
tvar
Cisco ubr10k bonding on MC5x20 + SPA24XDS SFP without TC1000

Hi all.

I needed some help.

I made a config with 20x20V-20D + SPA24XDS without TC1000. 25DSx8US bonding. It works fine.
I want to made it with MC5x20 + SPA24XDS card too.
All DS and US bonding group is OK, everething looks fine, but the modem after a reject(na) state starts again to search the DS and after the the CM is online only in 1x1 without any bonding.

5x20 is in the 5/1 slot. SPA24XDS is in the 1/0/0 slot.

Here is the config and some output:

5x20_US_bonding#show cable fiber-node
---------------------------------------------------------------------------------

Fiber-Node 1
Channel(s) : downstream Modular-Cable 1/0/0: 0-23
Channel ID(s): 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
Channel : downstream Cable 5/1/0
Channel ID : 1
upstream Cable 5/1: 0-7
FN Config Status: Configured (status flags = 0x01)
MDD Status: Valid
5x20_US_bonding#
5x20_US_bonding#

5x20_US_bonding#show cable mac-domain cable 5/1/0 downstream-service-group
Cable MD-DS-SG RF
IF Id Resource Chan Primary Chan
C5/1/0 1 1/0/0 00-23 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
5/1/0 00 0

5x20_US_bonding#show cable mac-domain cable 5/1/0 upstream-service-group
Cable MD 5/1/0
US-SG-ID : 1 US-Chan : U0,1,2,3,4,5,6,7
Primary-DS: 5/1/0:0 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:0 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:1 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:2 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:3 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:4 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:5 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:6 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:7 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:8 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:9 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:10 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:11 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:12 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:13 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:14 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:15 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:16 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:17 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:18 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:19 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:20 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:21 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:22 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7
Primary-DS: 1/0/0:23 US-SG-ID: 1
MDD US-List : U0,1,2,3,4,5,6,7
MDD Ambiguity : U0,1,2,3,4,5,6,7

5x20_US_bonding#

Config:

!
version 12.2
no service pad
service timestamps debug datetime msec
service timestamps log datetime msec
no service password-encryption
!
hostname 5x20_US_bonding
!
boot-start-marker
boot system disk0:ubr10k4-k9p6u2-mz.122-33.SCJ2a.bin
boot-end-marker
!
logging console informational
!
no aaa new-model
facility-alarm outlet-temperature major 58
facility-alarm outlet-temperature minor 48
facility-alarm intake-temperature major 54
facility-alarm intake-temperature minor 45
!
!
!
card 1 4jacket-1
card 1/0 24rfchannel-spa-1
card 2/1 2cable-dtcc
card 5/1 5cable-mc520h-d
cable snmp iftype ds-phy 1
cable admission-control preempt priority-voice
!
!
!
!
cable modem remote-query 30 public
cable modem v6-max-cpe-prefix 16
cable modulation-profile 222 request 0 16 0 22 qpsk scrambler 152 no-diff 36 fixed qpsk0 1 2048
cable modulation-profile 222 initial 5 34 0 48 qpsk scrambler 152 no-diff 98 fixed qpsk0 1 2048
cable modulation-profile 222 station 5 34 0 48 qpsk scrambler 152 no-diff 98 fixed qpsk0 1 2048
cable modulation-profile 222 a-short 3 76 12 22 qpsk scrambler 152 no-diff 64 shortened qpsk0 1 2048
cable modulation-profile 222 a-long 9 232 0 22 qpsk scrambler 152 no-diff 64 shortened qpsk0 1 2048
cable modulation-profile 222 a-ugs 9 232 0 22 qpsk scrambler 152 no-diff 64 shortened qpsk0 1 2048
cable modulation-profile 223 request 0 16 0 22 16qam scrambler 152 no-diff 36 fixed qpsk1 1 2048
cable modulation-profile 223 initial 5 34 0 48 16qam scrambler 152 no-diff 98 fixed qpsk1 1 2048
cable modulation-profile 223 station 5 34 0 48 16qam scrambler 152 no-diff 98 fixed qpsk1 1 2048
cable modulation-profile 223 a-short 4 76 7 22 16qam scrambler 152 no-diff 64 shortened qpsk1 1 2048
cable modulation-profile 223 a-long 9 232 0 22 16qam scrambler 152 no-diff 64 shortened qpsk1 1 2048
cable modulation-profile 223 a-ugs 9 232 0 22 16qam scrambler 152 no-diff 64 shortened qpsk1 1 2048
cable modulation-profile 224 request 0 16 0 22 qpsk scrambler 152 no-diff 36 fixed qpsk0 1 2048
cable modulation-profile 224 initial 5 34 0 48 qpsk scrambler 152 no-diff 98 fixed qpsk0 1 2048
cable modulation-profile 224 station 5 34 0 48 qpsk scrambler 152 no-diff 98 fixed qpsk0 1 2048
cable modulation-profile 224 a-short 5 76 6 22 32qam scrambler 152 no-diff 64 shortened qpsk1 1 2048
cable modulation-profile 224 a-long 9 232 0 22 32qam scrambler 152 no-diff 64 shortened qpsk1 1 2048
cable modulation-profile 224 a-ugs 9 232 0 22 32qam scrambler 152 no-diff 64 shortened qpsk1 1 2048
cable service attribute ds-bonded downstream-type bonding-enabled enforce
no cable qos permission create
no cable qos permission update
cable qos permission modems
!
cable logging badipsource
cable logging layer2events
cable logging overlapip
cable logging ironbus
cable logging downstream-index
!
!
ip subnet-zero
ip ftp username bax
ip ftp password bax
no ip domain lookup
ip dhcp-server 10.252.0.100
ip dhcp relay information option
no ip dhcp relay information check
!
!
!
!
l2tp-class l2tpclass
hello 5
retransmit retries 5
retransmit timeout max 1
!
l2tp-class RFGW
hello 1
retransmit retries 10
retransmit initial retries 10
!
depi-class depiclass
mode mpt
!
depi-class RFGW
mode mpt
!
depi-tunnel tunel-1
dest-ip 10.0.0.2
tos 100
l2tp-class RFGW
depi-class RFGW
!
!
!
!
redundancy
mode sso
!
controller Modular-Cable 1/0/0
modular-host subslot 5/1
rf-channel 0 cable downstream channel-id 2
rf-channel 0 frequency 328000000 annex A modulation 256qam interleave 12
rf-channel 0 depi-tunnel tunel-1 tsid 401
rf-channel 0 rf-power 50.0
no rf-channel 0 rf-shutdown
rf-channel 1 cable downstream channel-id 3
rf-channel 1 frequency 336000000 annex A modulation 256qam interleave 12
rf-channel 1 depi-tunnel tunel-1 tsid 402
rf-channel 1 rf-power 50.0
no rf-channel 1 rf-shutdown
rf-channel 2 cable downstream channel-id 4
rf-channel 2 frequency 344000000 annex A modulation 256qam interleave 12
rf-channel 2 depi-tunnel tunel-1 tsid 403
rf-channel 2 rf-power 50.0
no rf-channel 2 rf-shutdown
rf-channel 3 cable downstream channel-id 5
rf-channel 3 frequency 352000000 annex A modulation 256qam interleave 12
rf-channel 3 depi-tunnel tunel-1 tsid 404
rf-channel 3 rf-power 50.0
no rf-channel 3 rf-shutdown
rf-channel 4 cable downstream channel-id 6
rf-channel 4 frequency 360000000 annex A modulation 256qam interleave 12
rf-channel 4 depi-tunnel tunel-1 tsid 405
rf-channel 4 rf-power 50.0
no rf-channel 4 rf-shutdown
rf-channel 5 cable downstream channel-id 7
rf-channel 5 frequency 368000000 annex A modulation 256qam interleave 12
rf-channel 5 depi-tunnel tunel-1 tsid 406
rf-channel 5 rf-power 50.0
no rf-channel 5 rf-shutdown
rf-channel 6 cable downstream channel-id 8
rf-channel 6 frequency 376000000 annex A modulation 256qam interleave 12
rf-channel 6 depi-tunnel tunel-1 tsid 407
rf-channel 6 rf-power 50.0
no rf-channel 6 rf-shutdown
rf-channel 7 cable downstream channel-id 9
rf-channel 7 frequency 384000000 annex A modulation 256qam interleave 12
rf-channel 7 depi-tunnel tunel-1 tsid 408
rf-channel 7 rf-power 50.0
no rf-channel 7 rf-shutdown
rf-channel 8 cable downstream channel-id 10
rf-channel 8 frequency 392000000 annex A modulation 256qam interleave 12
rf-channel 8 depi-tunnel tunel-1 tsid 409
rf-channel 8 rf-power 50.0
no rf-channel 8 rf-shutdown
rf-channel 9 cable downstream channel-id 11
rf-channel 9 frequency 400000000 annex A modulation 256qam interleave 12
rf-channel 9 depi-tunnel tunel-1 tsid 410
rf-channel 9 rf-power 50.0
no rf-channel 9 rf-shutdown
rf-channel 10 cable downstream channel-id 12
rf-channel 10 frequency 408000000 annex A modulation 256qam interleave 12
rf-channel 10 depi-tunnel tunel-1 tsid 411
rf-channel 10 rf-power 50.0
no rf-channel 10 rf-shutdown
rf-channel 11 cable downstream channel-id 13
rf-channel 11 frequency 416000000 annex A modulation 256qam interleave 12
rf-channel 11 depi-tunnel tunel-1 tsid 412
rf-channel 11 rf-power 50.0
no rf-channel 11 rf-shutdown
rf-channel 12 cable downstream channel-id 14
rf-channel 12 frequency 424000000 annex A modulation 256qam interleave 12
rf-channel 12 depi-tunnel tunel-1 tsid 413
rf-channel 12 rf-power 50.0
no rf-channel 12 rf-shutdown
rf-channel 13 cable downstream channel-id 15
rf-channel 13 frequency 432000000 annex A modulation 256qam interleave 12
rf-channel 13 depi-tunnel tunel-1 tsid 414
rf-channel 13 rf-power 50.0
no rf-channel 13 rf-shutdown
rf-channel 14 cable downstream channel-id 16
rf-channel 14 frequency 440000000 annex A modulation 256qam interleave 12
rf-channel 14 depi-tunnel tunel-1 tsid 415
rf-channel 14 rf-power 50.0
no rf-channel 14 rf-shutdown
rf-channel 15 cable downstream channel-id 17
rf-channel 15 frequency 448000000 annex A modulation 256qam interleave 12
rf-channel 15 depi-tunnel tunel-1 tsid 416
rf-channel 15 rf-power 50.0
no rf-channel 15 rf-shutdown
rf-channel 16 cable downstream channel-id 18
rf-channel 16 frequency 456000000 annex A modulation 256qam interleave 12
rf-channel 16 depi-tunnel tunel-1 tsid 417
rf-channel 16 rf-power 50.0
no rf-channel 16 rf-shutdown
rf-channel 17 cable downstream channel-id 19
rf-channel 17 frequency 464000000 annex A modulation 256qam interleave 12
rf-channel 17 depi-tunnel tunel-1 tsid 418
rf-channel 17 rf-power 50.0
no rf-channel 17 rf-shutdown
rf-channel 18 cable downstream channel-id 20
rf-channel 18 frequency 472000000 annex A modulation 256qam interleave 12
rf-channel 18 depi-tunnel tunel-1 tsid 419
rf-channel 18 rf-power 50.0
no rf-channel 18 rf-shutdown
rf-channel 19 cable downstream channel-id 21
rf-channel 19 frequency 480000000 annex A modulation 256qam interleave 12
rf-channel 19 depi-tunnel tunel-1 tsid 420
rf-channel 19 rf-power 50.0
no rf-channel 19 rf-shutdown
rf-channel 20 cable downstream channel-id 22
rf-channel 20 frequency 488000000 annex A modulation 256qam interleave 12
rf-channel 20 depi-tunnel tunel-1 tsid 421
rf-channel 20 rf-power 50.0
no rf-channel 20 rf-shutdown
rf-channel 21 cable downstream channel-id 23
rf-channel 21 frequency 496000000 annex A modulation 256qam interleave 12
rf-channel 21 depi-tunnel tunel-1 tsid 422
rf-channel 21 rf-power 50.0
no rf-channel 21 rf-shutdown
rf-channel 22 cable downstream channel-id 24
rf-channel 22 frequency 504000000 annex A modulation 256qam interleave 12
rf-channel 22 depi-tunnel tunel-1 tsid 423
rf-channel 22 rf-power 50.0
no rf-channel 22 rf-shutdown
rf-channel 23 cable downstream channel-id 25
rf-channel 23 frequency 512000000 annex A modulation 256qam interleave 12
rf-channel 23 depi-tunnel tunel-1 tsid 424
rf-channel 23 rf-power 50.0
no rf-channel 23 rf-shutdown
!
!
!
!
!
!
interface FastEthernet0/0/0
ip address 10.252.0.60 255.255.255.0 secondary
ip address 192.168.1.60 255.255.255.0
media-type rj45
speed 100
full-duplex
!
interface GigabitEthernet1/0/0
ip address 10.0.0.1 255.255.255.0
negotiation auto
!
interface Modular-Cable1/0/0:0
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:1
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:2
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:3
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:4
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:5
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:6
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:7
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:8
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:9
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:10
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:11
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:12
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:13
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:14
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:15
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:16
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:17
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:18
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:19
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:20
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:21
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:22
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Modular-Cable1/0/0:23
cable bundle 1
cable rf-bandwidth-percent 10 remaining ratio 100
!
interface Wideband-Cable1/0/0:0
cable bundle 1
cable rf-channel 0 bandwidth-percent 10 remaining ratio 100
cable rf-channel 1 bandwidth-percent 10 remaining ratio 100
cable rf-channel 2 bandwidth-percent 10 remaining ratio 100
cable rf-channel 3 bandwidth-percent 10 remaining ratio 100
cable rf-channel 4 bandwidth-percent 10 remaining ratio 100
cable rf-channel 5 bandwidth-percent 10 remaining ratio 100
cable rf-channel 6 bandwidth-percent 10 remaining ratio 100
cable rf-channel 7 bandwidth-percent 10 remaining ratio 100
cable rf-channel 8 bandwidth-percent 10 remaining ratio 100
cable rf-channel 9 bandwidth-percent 10 remaining ratio 100
cable rf-channel 10 bandwidth-percent 10 remaining ratio 100
cable rf-channel 11 bandwidth-percent 10 remaining ratio 100
cable rf-channel 12 bandwidth-percent 10 remaining ratio 100
cable rf-channel 13 bandwidth-percent 10 remaining ratio 100
cable rf-channel 14 bandwidth-percent 10 remaining ratio 100
cable rf-channel 15 bandwidth-percent 10 remaining ratio 100
cable rf-channel 16 bandwidth-percent 10 remaining ratio 100
cable rf-channel 17 bandwidth-percent 10 remaining ratio 100
cable rf-channel 18 bandwidth-percent 10 remaining ratio 100
cable rf-channel 19 bandwidth-percent 10 remaining ratio 100
cable rf-channel 20 bandwidth-percent 10 remaining ratio 100
cable rf-channel 21 bandwidth-percent 10 remaining ratio 100
cable rf-channel 22 bandwidth-percent 10 remaining ratio 100
cable rf-channel 23 bandwidth-percent 10 remaining ratio 100
!
interface Cable5/1/0
downstream local upstream 0-7
cable mtc-mode
cable udc-capability
no cable packet-cache
cable default-phy-burst 4000
cable bundle 1
cable downstream channel-id 1
cable downstream annex A
cable downstream modulation 256qam
cable downstream frequency 320000000
no cable downstream rf-shutdown
cable downstream rf-power 50
cable upstream max-ports 8
cable upstream bonding-group 1
upstream 0
upstream 1
upstream 2
upstream 3
upstream 4
upstream 5
upstream 6
upstream 7
attributes 80000000
cable upstream 0 connector 0
cable upstream 0 frequency 7000000
cable upstream 0 channel-width 1600000 1600000
cable upstream 0 docsis-mode atdma
cable upstream 0 minislot-size 4
cable upstream 0 range-backoff 3 6
cable upstream 0 modulation-profile 222
cable upstream 0 rate-limit
no cable upstream 0 shutdown
cable upstream 1 connector 1
cable upstream 1 frequency 8600000
cable upstream 1 channel-width 1600000 1600000
cable upstream 1 docsis-mode atdma
cable upstream 1 minislot-size 4
cable upstream 1 range-backoff 3 6
cable upstream 1 modulation-profile 222
cable upstream 1 rate-limit
no cable upstream 1 shutdown
cable upstream 2 connector 2
cable upstream 2 frequency 10200000
cable upstream 2 channel-width 1600000 1600000
cable upstream 2 docsis-mode atdma
cable upstream 2 minislot-size 4
cable upstream 2 range-backoff 3 6
cable upstream 2 modulation-profile 222
cable upstream 2 rate-limit
no cable upstream 2 shutdown
cable upstream 3 connector 3
cable upstream 3 frequency 11800000
cable upstream 3 channel-width 1600000 1600000
cable upstream 3 docsis-mode atdma
cable upstream 3 minislot-size 4
cable upstream 3 range-backoff 3 6
cable upstream 3 modulation-profile 222
cable upstream 3 rate-limit
no cable upstream 3 shutdown
cable upstream 4 connector 4
cable upstream 4 frequency 13400000
cable upstream 4 channel-width 1600000 1600000
cable upstream 4 docsis-mode atdma
cable upstream 4 minislot-size 4
cable upstream 4 range-backoff 3 6
cable upstream 4 modulation-profile 222
cable upstream 4 rate-limit
no cable upstream 4 shutdown
cable upstream 5 connector 5
cable upstream 5 frequency 15000000
cable upstream 5 channel-width 1600000 1600000
cable upstream 5 docsis-mode atdma
cable upstream 5 minislot-size 4
cable upstream 5 range-backoff 3 6
cable upstream 5 modulation-profile 222
cable upstream 5 rate-limit
no cable upstream 5 shutdown
cable upstream 6 connector 6
cable upstream 6 frequency 16600000
cable upstream 6 channel-width 1600000 1600000
cable upstream 6 docsis-mode atdma
cable upstream 6 minislot-size 4
cable upstream 6 range-backoff 3 6
cable upstream 6 modulation-profile 222
cable upstream 6 rate-limit
no cable upstream 6 shutdown
cable upstream 7 connector 7
cable upstream 7 frequency 18200000
cable upstream 7 channel-width 1600000 1600000
cable upstream 7 docsis-mode atdma
cable upstream 7 minislot-size 4
cable upstream 7 range-backoff 3 6
cable upstream 7 modulation-profile 222
cable upstream 7 rate-limit
no cable upstream 7 shutdown
!
interface Cable5/1/1
no cable packet-cache
cable downstream channel-id 29
cable downstream annex B
cable downstream modulation 64qam
cable downstream interleave-depth 32
cable downstream rf-shutdown
cable upstream max-ports 4
no cable upstream 0 connector
cable upstream 0 channel-width 1600000 1600000
cable upstream 0 docsis-mode atdma
cable upstream 0 minislot-size 4
cable upstream 0 range-backoff 3 6
cable upstream 0 modulation-profile 221
cable upstream 0 shutdown
no cable upstream 1 connector
cable upstream 1 channel-width 1600000 1600000
cable upstream 1 docsis-mode atdma
cable upstream 1 minislot-size 4
cable upstream 1 range-backoff 3 6
cable upstream 1 modulation-profile 221
cable upstream 1 shutdown
no cable upstream 2 connector
cable upstream 2 channel-width 1600000 1600000
cable upstream 2 docsis-mode atdma
cable upstream 2 minislot-size 4
cable upstream 2 range-backoff 3 6
cable upstream 2 modulation-profile 221
cable upstream 2 shutdown
no cable upstream 3 connector
cable upstream 3 channel-width 1600000 1600000
cable upstream 3 docsis-mode atdma
cable upstream 3 minislot-size 4
cable upstream 3 range-backoff 3 6
cable upstream 3 modulation-profile 221
cable upstream 3 shutdown
!
interface Cable5/1/2
no cable packet-cache
cable downstream channel-id 33
cable downstream annex B
cable downstream modulation 64qam
cable downstream interleave-depth 32
cable downstream rf-shutdown
cable upstream max-ports 4
no cable upstream 0 connector
cable upstream 0 channel-width 1600000 1600000
cable upstream 0 docsis-mode atdma
cable upstream 0 minislot-size 4
cable upstream 0 range-backoff 3 6
cable upstream 0 modulation-profile 221
cable upstream 0 shutdown
no cable upstream 1 connector
cable upstream 1 channel-width 1600000 1600000
cable upstream 1 docsis-mode atdma
cable upstream 1 minislot-size 4
cable upstream 1 range-backoff 3 6
cable upstream 1 modulation-profile 221
cable upstream 1 shutdown
no cable upstream 2 connector
cable upstream 2 channel-width 1600000 1600000
cable upstream 2 docsis-mode atdma
cable upstream 2 minislot-size 4
cable upstream 2 range-backoff 3 6
cable upstream 2 modulation-profile 221
cable upstream 2 shutdown
no cable upstream 3 connector
cable upstream 3 channel-width 1600000 1600000
cable upstream 3 docsis-mode atdma
cable upstream 3 minislot-size 4
cable upstream 3 range-backoff 3 6
cable upstream 3 modulation-profile 221
cable upstream 3 shutdown
!
interface Cable5/1/3
no cable packet-cache
cable downstream channel-id 37
cable downstream annex B
cable downstream modulation 64qam
cable downstream interleave-depth 32
cable downstream rf-shutdown
cable upstream max-ports 4
no cable upstream 0 connector
cable upstream 0 channel-width 1600000 1600000
cable upstream 0 docsis-mode atdma
cable upstream 0 minislot-size 4
cable upstream 0 range-backoff 3 6
cable upstream 0 modulation-profile 221
cable upstream 0 shutdown
no cable upstream 1 connector
cable upstream 1 channel-width 1600000 1600000
cable upstream 1 docsis-mode atdma
cable upstream 1 minislot-size 4
cable upstream 1 range-backoff 3 6
cable upstream 1 modulation-profile 221
cable upstream 1 shutdown
no cable upstream 2 connector
cable upstream 2 channel-width 1600000 1600000
cable upstream 2 docsis-mode atdma
cable upstream 2 minislot-size 4
cable upstream 2 range-backoff 3 6
cable upstream 2 modulation-profile 221
cable upstream 2 shutdown
no cable upstream 3 connector
cable upstream 3 channel-width 1600000 1600000
cable upstream 3 docsis-mode atdma
cable upstream 3 minislot-size 4
cable upstream 3 range-backoff 3 6
cable upstream 3 modulation-profile 221
cable upstream 3 shutdown
!
interface Cable5/1/4
no cable packet-cache
cable downstream channel-id 41
cable downstream annex B
cable downstream modulation 64qam
cable downstream interleave-depth 32
cable downstream rf-shutdown
cable upstream max-ports 4
no cable upstream 0 connector
cable upstream 0 channel-width 1600000 1600000
cable upstream 0 docsis-mode atdma
cable upstream 0 minislot-size 4
cable upstream 0 range-backoff 3 6
cable upstream 0 modulation-profile 221
cable upstream 0 shutdown
no cable upstream 1 connector
cable upstream 1 channel-width 1600000 1600000
cable upstream 1 docsis-mode atdma
cable upstream 1 minislot-size 4
cable upstream 1 range-backoff 3 6
cable upstream 1 modulation-profile 221
cable upstream 1 shutdown
no cable upstream 2 connector
cable upstream 2 channel-width 1600000 1600000
cable upstream 2 docsis-mode atdma
cable upstream 2 minislot-size 4
cable upstream 2 range-backoff 3 6
cable upstream 2 modulation-profile 221
cable upstream 2 shutdown
no cable upstream 3 connector
cable upstream 3 channel-width 1600000 1600000
cable upstream 3 docsis-mode atdma
cable upstream 3 minislot-size 4
cable upstream 3 range-backoff 3 6
cable upstream 3 modulation-profile 221
cable upstream 3 shutdown
!
interface Bundle1
ip address 10.10.2.1 255.255.255.0 secondary
ip address 10.10.1.1 255.255.255.0
cable arp filter request-send 3 2
cable arp filter reply-accept 3 2
cable dhcp-giaddr policy
cable helper-address 10.252.0.100
!
ip classless
ip route 0.0.0.0 0.0.0.0 192.168.1.254
!
!
no ip http server
no ip http secure-server
!
!
logging cmts ipc-cable log-level errors
logging cmts sea syslog-level errors
cpd cr-id 1
nls resp-timeout 1
cdp run
!
snmp-server engineID local 8000000904697361737A6567
snmp-server manager
!
!
control-plane
!
!
line con 0
password xxx
stopbits 1
line aux 0
password xxx
stopbits 1
line vty 0 3
password xxx
login
line vty 4
login
!
scheduler isr-watchdog
!
cable fiber-node 1
downstream Cable 5/1/0
downstream Modular-Cable 1/0/0 rf-channel 0-23
upstream Cable 5/1 connector 0-7
!
end

Thank you!

mbowe
You need to include a primary DS

Each bonding group needs to include at least one primary DS.

SPA card DS cannot be made primary without a DTI server.

A bonding group can only comprise of onboard DS or SPA DS, cannot be a mix of both

Without a DTI, the SPA cards are not super useful.

I previously provided some examples of 20x20 and SPA here
https://www.docsis.org/comment/5866#comment-5866

If you are struggling to get good solutions with the 5x20 card I would recommend you ditch it and replace with 20x20. The 20x20 cards are available for next to nothing these days on the 2nd hand market. SPA 24 cards are also super cheap. Unfortunately, DTI servers don't seem to be super common or cheap.

Log in or register to post comments